Several Bunch Modes in 2007
in and before 2006 | 2007 | 2008 | 2009 | 2010 | 2011 | 2012 | 2013| 2014 | 2015 | 2016 | 2017 | current
Several Bunch Modes in the first half of 2007, 2007A
Mode | Bunch mode*1 | Bunch interval*2 | Total current |
Single bunch current*3 |
Beam injection interval |
A-mode | 203 bunches | 23.6 nsec | 100 mA | 1 minute | |
B-mode | 4 bunch train x 84 | 51.1 nsec (57.0 nsec period) |
100 mA | 1 minute | |
C-mode | 11 bunch train x 29 | 145.5 nsec (165.2 nsec period) |
100 mA | 1 minute | |
D-mode | 1/7-filling + 5 bunches | 684.3 nsec | 100 mA | 3.0 mA | 1 minute |
E-mode | 2/29-filling + 26 bunches | 165.2 nsec | 100 mA | 1.4 mA | 1 minute |
Several Bunch Modes in the second half of 2007, 2007B
Mode | Bunch mode*1 | Bunch interval*2 | Total current |
Single bunch current*3 |
Beam injection interval |
A-mode | 203 bunches | 23.6 nsec | 100 mA | 1 minute | |
B-mode | 4 bunch train x 84 | 51.1 nsec (57.0 nsec period) |
100 mA | 1 minute | |
C-mode | 11 bunch train x 29 | 145.5 nsec (165.2 nsec period) |
100 mA | 1 minute | |
D-mode | 1/14-filling + 12 bunches | 342.1 nsec | 100 mA | 1.6 mA | 1 minute |
E-mode | 4/58-filling + 53 bunches | 82.6 nsec | 100 mA | 1.0 mA | 1 minute |
*1 The actual bunch mode is subject to change slightly due to the instability of the electrons in the ring. The tabulated bunch interval is retained.
*2 The time interval of the successive bunches is 1.966 nsec.
*3 Single bunch current at injection is subject to change depending on the ring conditions.
You can download the text file (a CSV file) which shows the time structure of the above listed bunch mode. Draw the figure of the time structure taking time (nsec) as x-axis and current (mA) as Y-axis with your own graphic software.
Contact: , Research Coordination Division