ナビゲーション


BL02B2 OUTLINE

問い合わせ番号

INS-0000000318

ABSTRACT

  The BL02B2 is a beamline for powder diffraction using high-energy synchrotron radiation, and is designed for charge density study by powder specimens in the area of materials science. There is powder diffractometer with multi modular system constructed by six MYTHEN detector in experimental hutch. The beamline optics covers x-ray energy range from 12 keV to 37 keV. This beamline makes it possible to collect powder diffraction data with a high-counting statistics and high-angular resolution, which must contribute the improvement of the accuracy of structure analysis of crystalline materials.

AREA OF RESEARCH

  • Charge density studies closely related to properties of functional materials
  • Structural aspects of phase transition
  • Ab initio structure determination using powder diffraction data
  • Structural refinements by Rietveld method
  • In-situ powder diffraction experiment under gas and vapor adsorption/desorption

KEYWORDS

  • Scientific field
    High-energy synchrotron radiation powder diffraction, Powder diffraction under extreme conditions  
  • Equipment
    Micro-strip MYTHEN detector, High and low temperature N2 gas flow device, Large Debye-Scherrer camera, Flat panel detector, Automatic sample changer
  • Ancillary equipment
    Helium gas flow temperature control device, Laser and xenon lamp for photo induced experiment, In-situ measurement system for gas adsorption, Cryostat, Furnace

SOURCE AND OPTICS

The main optical components are a Si (1 1 1) double-crystal monochromator and a vertical focusing mirror for eliminating high energy harmonics. 

  • X-rays at Sample

    Energy range 12 - 37 keV
    Energy resolution ΔE/E = ~2 × 10-4
    Photon flux - 1011 photons/s
    Beam size 3.0(H) × 0.5(V) mm2

  • Schematic View of Beamline
    Schematic View of Beamline
    Schematic View of Beamline

EXPERIMENTAL STATIONS

Reference

J. Synchrotron Rad., 27 (2020) 616–624.
Review of Scientific Instruments, 88 (2017) 085111.
Nuclear Instruments and Methods in Physics Research A, 467-468 (2001) 1045.

PUBLICATION SEARCH

* Sorry, Some parts of results are displayed using Japanese characters.

BL02B2 PUBLICATION SEARCH

CONTACT INFORMATION

Please note that each e-mail address is followed by "@spring8.or.jp."

Shogo KAWAGUCHI
SPring-8 / JASRI
1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198
Phone : +81-(0)791-58-0833
Fax : +81-(0)791-58-0830
e-mail : kawaguchi

Hiroki YAMADA
SPring-8 / JASRI
1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198
Phone : +81-(0)791-58-0833
Fax : +81-(0)791-58-0830
e-mail : h_yamada

Shintaro KOBAYASHI
SPring-8 / JASRI
1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198
Phone : +81-(0)791-58-0833
Fax : +81-(0)791-58-0830
e-mail : kobayashi.shintaro

Yuki MORI
SPring-8 / JASRI
1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198
Phone : +81-(0)791-58-0833
Fax : +81-(0)791-58-0830
e-mail : yuki.mori

最終変更日
カレンダー